Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-64Add IP Interface Assembly
6
Administration Steps
1. Log in as
craft
.
2. Type
change circuit-pack
and press
Enter.
3. Check the Code column to see if the slots above the TN802B say
DSMAPD or MEDPRO.
.
4. If MEDPRO, go to the entry just above the TN802B that says MEDPRO.
5. Type DSMAPD, and press
Enter. Changing the one entry automatically
changes the entry above it. If it is in IP Trunk mode, you get the following
error message:
MedPro type requires TN802 with application. Type
MEDPRO on circuit-packs form.
Log onto the TN802B Interface Server
If administered remotely through pcANYWHERE:
1. Dial in to the server through pcANYWHERE using the dialup number
supplied.
2. Click on the pcANYWHERE Remote Host Computer button on the toolbar
to send
CTRL ALT DEL to the host.
3. Type
administrator
in the
User Name
field.
4. Type
iptrunk
in the
Password
field and click
OK
.
5. After logging on for the first time, change the administrator password and,
if desired, the user name, to ensure security. See your Windows NT server
documentation for details.
change circuit-packs Page 1 of 5
CIRCUIT PACKS
Cabinet: 1 Carrier: A
Carrier Type: processor
Slot Code Sf Mode Name Slot Code Sf Mode Name
11: DSMAPD RESERVED-IP
01: TN754 DIGITAL LINE 12: DSMAPD RESERVED-IP
02: TN758 POOLED MODEM 13: TN802 B MAPD BOARD
03: TN2144 ANALOG LINE 14:
04: TN746 B ANALOG LINE 15:
05 16:
06: TN771 C MAINTENANCE/TEST
07: TN464 F DS1 INTERFACE
08: TN2140 E&M TIE TRUNK
09: TN767 E DS1 INTERFACE
10: TN799 B CONTROL-LAN
’#’ indicates circuit pack conflict.