Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Upgrading G3rV2, V3, V4 to R8r and Adding Memory
1-6Upgrade the software and hardware
1
Upgrade the software and hardware
Check SPE
1. Type
status spe
and press Enter to check the health of the SPE.
For high or critical reliability systems:
The
Standby Refreshed
field shows
yes
The
Standby Shadowing
field shows
on
The
Standby Handshake
field shows
up
Save Translations
1. Type
save translation
and press Enter to write all translation information
from memory to the disk, which takes about 2 minutes.
Save Announcements (if necessary)
NOTE:
The TN750C Announcement circuit pack stores announcements in
nonvolatile memory; saving the announcements is optional.
1. If the PPN contains a TN750/B Announcement circuit pack, type
display
announcements
and press
Enter.
2. If administered recorded announcements are listed, type
save
announcements
cabinet carrier slot
and press Enter. For example,
01
D03. This takes about 30 minutes.
NOTE:
For some software loads, type
save announcements from
cabinet
carrier slot
. Type
help
and press Enter for complete command
usage.
Back Up Disk
1. Type
backup disk
and press Enter to write all information from the disk to
the backup tape. This takes 30 to 40 minutes.