Adding or Removing Cabinet Hardware
6-78Add IP Interface Assembly
6
Circuit Pack Verification
1. Type
change circuit-pack
and press Enter.
2. Check the Code column to see if it says DSMAPD or MedPro.
.
3. To correct it, go to the entry just above the TN802B that says DSMAPD.
4. Type MEDPRO, and press
Enter. Changing the one entry automatically
changes the entry above it. If it is in IP Trunk mode, you get the following
error message:
MedPro type requires TN802 with application. Type
MEDPRO on circuit-packs form.
5. To complete the administration, refer to the
DEFINITY ECS Release 8
Network Connectivity
book.
change circuit-packs Page 1 of 5
CIRCUIT PACKS
Cabinet: 1 Carrier: A
Carrier Type: processor
Slot Code Sf Mode Name Slot Code Sf Mode Name
11: MEDPRO RESERVED-IP
01: TN754 DIGITAL LINE 12: MEDPRO RESERVED-IP
02: TN758 POOLED MODEM 13: TN802 B MAPD BOARD
03: TN2144 ANALOG LINE 14:
04: TN746 B ANALOG LINE 15:
05 16:
06: TN771 C MAINTENANCE/TEST
07: TN464 F DS1 INTERFACE
08: TN2140 E&M TIE TRUNK
09: TN767 E DS1 INTERFACE
10: TN799 B CONTROL-LAN
’#’ indicates circuit pack conflict.