Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Upgrading G3rV2, V3, V4 to R8r and Adding Memory
1-21Upgrade the software and hardware
1
Release MMI (H/C only)
1. Type
release board
cabinet carrier slot
and press
Enter to release the
circuit packs, which were busied out earlier.
Resolve Alarms
1. Type
display alarms
and press Enter to examine the alarm log. Resolve
any alarms that may exist using
DEFINITY Enterprise Communications
Server Release 8 Maintenance for R8r
.
Check Link Status
1. Type
display communication-interface links
and press Enter. Compare it
with the earlier status.
2. Type
status link
number
and press Enter. Repeat this step for each link.
Enable Scheduled Maintenance
1. Type
change system-parameters maintenance
and press Enter.
2. Type the appropriate time in the
Start
field to enable scheduled daily
maintenance. Make sure the
Save Translation
field is set to
daily
.
Enable Customer Options and Alarm Origination
to INADS
1. Get the DOSS order number of the upgrade from the project manager and
ask the regional Customer Software Administration to complete the steps
in the shaded box. See ‘‘Where to Call for Technical Support’’ on page -xx
for telephone numbers.
NOTE:
As part of the system registration process, the INADS Database
Administrator enables Alarm Origination and customer options.
2. When administration is completed, log in as
craft
at the
Login:
prompt.