Adding or Removing Cabinet Hardware
6-102Add a Switch Node Carrier (Standard Reliability)
6
9. If a switch node carrier was installed in the “D” position, verify that the
ZAHF4 TDM/LAN bus terminator is installed at slot 02 of the switch node
carrier “D”. See
Figure 6-36
.
If a switch node carrier is being installed in the “E” position, verify that the
ZAHF4 TDM/LAN bus terminator is installed at slot 21.
10. Install the front trim plates on the “D” carrier.
11. Install the new power units into the “D” carrier. Install a 649A on the left
and right sides of the carrier.
12. Connect the power cords to the power units. The power cords are the
white cables equipped with plugs that are run through the slots in the front
of each carrier.