Adding or Removing Cabinet Hardware
6-57Add IP Interface Assembly
6
Check your Shipment
When your DEFINITY ECS order arrives at the customer’s site, check the
contents (see
Table 6-6
).
1. Inspect the shipping carton for damage before opening it. If the box is
damaged,
do not open it
. Inform the shipping company, and ask for
instructions on filing a claim.
2. If the box is undamaged, check the contents against the packing slip.
Check the condition of each component, and note any damage or
shortages on the packing slip. The carton should contain the following for
each IP Interface ordered:
.
The TN802B external cable assembly is a bundle of cables with an amphenol
connector at the end of the bundle and various PC-type connectors (VGA,
Universal Serial Bus [USB], mouse, keyboard, Ethernet, modem, and COM2) at
the ends of the individual cables. See
Figure 6-24
. Look for the label where the
bundle enters the amphenol connector.
Table 6-6. Required Hardware
Comcode/Code Description Quantity
J58890MA-1 L30 TN802B IP Interface Assembly
1
601939804 H600-512,G1 external cable assembly 1
407633999 U.S. Robotics Sportster external
modem, model number USR 33.6 EXT
(U.S. customers only)
1
1. For non-U.S. customers, you need a modem comparable to the U.S. Robotics
Sportster and a serial cable.
1
601087091 20-ft DB-25 serial cable from modem
to TN802B external cable assembly
(U.S. customers only)
2