Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Fiber Link Administration
A-19Administer Fiber Links
A
CRC Displays when the DS1 Converter circuit pack is TN1654 and the
Bit Rate is 2.048 Mbps. Enter
yes
to receive a “yellow 2” alarm for E1
operation. Default is
no
. You can administer this field on a per circuit pack
basis.
Line Termination
A display-only field for DS1 Converter circuit packs
that are TN1654 and have a Bit Rate of 2.048 Mbps. It identifies facility
connections as CEPT 75 ohm coaxial or 120 ohm CEPT twisted pair.
Duplicated DS1 Converter Complex Administration for E1 TN1654 Circuit
Packs.
See the previous sections for screen layout and field definitions.
Screen 6-7. Fiber Line Administration form for B-PNC DS1 Converter
(DS1CONV) Attributes
add fiber-link next Page 3 of 3
FIBER LINK ADMINISTRATION
B-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES
DS1CONV Board Location: 01C01 DS1CONV Board Location: 02C01
DS1CONV Board Type: TN1654 DS1CONV Board Type: TN1654
DS1 CONVERTER FACILITIES
ABC D
Facility Installed? yes yes yes no
Bit Rate: 2.048
Facility Startup Idle Code: 11101000
Line Coding: hdb3 hdb3 hdb3 hdb3
CRC? yes
Line Termination:
Facility A Circuit ID: 0AABB01
Facility B Circuit ID: 0CCDD02
Facility C Circuit ID: 0EEFF03