DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Upgrading G3rV2, V3, V4 to R8r and Adding Memory
1-8Upgrade the software and hardware
1
If high or critical reliability:
1. Type
configure tape spe-a large
and press
Enter to reconfigure the
removable media in control carrier “A” for 2 TN1650B Memory circuit
packs. This command takes about 1 minute to complete.
2. Type
configure tape spe-b large
and press
Enter to reconfigure the
removable media in control carrier “B” for 2 TN1650B Memory circuit
packs. This command takes about 1 minute to complete.
Check Link Status
1. Type
display communication-interface links
and press Enter. Write down
all enabled links.
2. Type
status link
number
and press Enter. Repeat this step for all links.
3. Write down which links are in service.
Disable TTI
NOTE:
Do this step only if the Terminal Translation Initialization (TTI) is enabled.
!
CAUTION:
If you do not disable the TTI, the translations can be corrupted.
Make sure the ISDN is in service. If not, try to busy out and release the ISDN
D-channel/link to bring the ISDN trunks back into service.
1. Type
change system-parameters features
and press
Enter.
2. On
the second screen, set the
TTI Enabled?
field to
n
to de-activate the
TTI feature.
Check Disk Drive
1. Type
list configuration control
and press Enter to check the vintage of the
disk drive. If the drive is V4 or later, go to
Check TTI Status
.
or
If the drive is
not
V4 or later, go to
Install Disk Drive (if not TN1657 V4 or
earlier).