DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Upgrading R5r/R6r/R7r to R8r without Adding Memory
2-16Upgrade the software and hardware
2
For high or critical reliability:
1. Type
upgrade software G3V8r.xx.x.xxx.x no-calls
(entire alphanumeric
string of new software version) and press
Enter. At the prompt, press Enter
to save translations and attempt to preserve calls across the interchange.
For all reliabilities:
2. After the system resets, log in as
craft
.
3. Check for the
Translation Corruption Detected
message before
proceeding with the upgrade. If corruption is detected, refer to No
Translations After Upgrade in
Appendix B, ‘‘Troubleshooting an Upgrade’’
to correct the problem.
!
CAUTION:
Do not continue with the upgrade until the translations errors are
corrected.
Reset SPE status (H/C only)
1. Type
status SPE
and press Enter. Wait until the
Standby Handshake
field displays
up, which takes about 3 minutes.
2. Type
reset spe-standby 4
and press
Enter.
NOTE:
You can continue the process while the SPE is resetting.
Set Daylight Savings Rules
You can set up to 15 customized daylight savings time rules. If you have cabinets
in several different time zones, you can set up rules for each on a location basis.
A daylight savings time rule specifies the exact time when you want to transition
to and from daylight savings time. It also specifies the increment at which to
transition.
NOTE:
The default daylight savings rule is
0
, no daylight savings.
1. Type
change daylight-savings-rules
and press
Enter.