Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-113Critical Reliability
5
Save Translations
1. Type
save translation
and press Enter to get upgraded translations onto
disk. If the translations were corrupted during the upgrade, the following
error message displays when logging in:
!
WARNING:
Translation corruption detected; call Lucent Technologies distributor
immediately.
NOTE:
The
save translation
command cannot function if the translation
corruption message appears. See
‘‘Troubleshooting an Upgrade’’ on
page B-1.
Back Up Disk
1. Type
backup disk
and press Enter to backup all changed files.
2. Type
test stored-data long
and press
Enter. This instructs the system to
verify the consistency of the MSS files (on the disk and removable media).
Return Replaced Equipment
Return replaced equipment to Lucent Technologies according to the
requirements outlined in:
BCS/Material Logistics, MSL/Attended Stocking Locations
Methods and Procedures for Basic Material Returns