Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-15Standard Reliability
5
Standard Reliability
Required Hardware
The equipment in Table 5-6 must be on-site before the upgrade begins. To place
a claim for missing equipment, as part of the Streamlined Implementation
process, call 1-800-772-5409, or the number provided by your Lucent
Technologies representative.
Table 5-6. Required Hardware
Equipment Description Quantity
PEC 6300-05X Processor Port Network 1
J58890AF-1 Expansion Control Carrier 1
106647985 TN775B Maintenance 1
103557294
or
103281788
TN776 Expansion Interface
TN570 Expansion Interface
2 or 6
1
2 or 6
1,2
1. Depending on the number of Release 8 EPNs. Two are required for a standard
reliability system with 2 port networks; 6 with 3 port networks. Either 1 or 4 Expansion
Interfaces (EIs) are shipped loose with the EPN equipment. The factory has installed
either 1 or 2 EIs in the new PPN.
2. Required port network interfaces in a Release 8 system with the optional packet bus.
407439975 20-Foot Multi-mode Fiber Optic Cable 1 or 3
3
3. Depending on the number of DEFINITY ECS Release 8 EPNs. Two or 6 are required
if the PPN and EPN(s) are remotely located. Assuming acceptable lengths, the fiber
that previously connected an upgraded G2 universal module (not a traditional
module) to the G2 TMS has the correct transceiver connectors and can be reused.
106455348
or
106455363
9823A Lightwave Transceiver
9823B Lightwave Transceiver
2 or 6
4
2 or 6
5
4. One pair for each fiber connection. For each connection, either 1 lightwave
transceiver is installed in an EPN and 1 in the PPN. A transceiver can be reused from
each upgraded G2 universal module. Additional transceivers, ordered separately,
are also shipped loose with the EPN equipment.