Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Upgrading R5si/R6si to R8r EPN and Adding Memory
3-13Release 5/6si to Release 8r
3
Shut Down DEFINITY LAN Gateway System
!
WARNING:
Neglecting to shut down a DEFINITY LAN Gateway assembly before
powering down the system cabinet can damage the LAN Gateway disk.
1. Log onto the DEFINITY LAN Gateway. See the
DEFINITY Communications
System Generic 3 Installation, Administration and Maintenance of
CallVisor ASAI over the DEFINITY LAN Gateway
for the procedure to log
on.
2. When the main menu appears, select
Maintenance
.
3. Select
Reset System
from the
Maintenance
menu.
4. Select
Shutdown
from the
Reset System
menu.
5. Unseat the LAN Gateway assembly from its backplane connectors.
Shut Down DEFINITY AUDIX System
1. If a DEFINITY AUDIX System resides in the system to be upgraded, shut
down the AUDIX assembly and allow the disk to completely spin down.
Refer to the
‘‘DEFINITY AUDIX Power Procedures’’
at the end of this
chapter.
!
WARNING:
Neglecting to shut down an AUDIX assembly before powering down
the system cabinet where it resides can damage the AUDIX disk.
2. Unseat the AUDIX assembly from its backplane connectors.
Power Down Existing System
1. At each PPN cabinet power supply, set the main circuit breaker to OFF.
!
CAUTION:
Powering down the PPN will cause important system data, such as
BCMS data, records of queued ACD calls, Automatic Wakeup
requests, and Do Not Disturb requests to be lost. Refer to DEFINITY
Enterprise Communications Server Release 8 Maintenance for R8r,
for information about preparing the system for a power down.
2. At each EPN cabinet power supply, set the main circuit breaker to OFF.