Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-94Critical Reliability
5
6. Behind control carrier A of EPN cabinet 3:
Install a lightwave transceiver on cable connector at slot 3A02.
Connect the other end of the fiber optic cable to the lightwave
transceiver, just installed, at slot 3A02.
Carefully attach the fiber optic cable (with cable ties) to the wall of
the cable tray at the built-in cable tie positions.
At the top of the cabinet, coil the surplus fiber optic cable, and
carefully attach the coil to the wall of the cable tray.
7. Behind port carrier B of EPN cabinet 2:
Install a lightwave transceiver on cable connector at slot 2B03.
Connect 1 end of the fiber optic cable to the lightwave transceiver,
just installed, at slot 2B03.
Carefully attach the fiber optic cable (with cable ties) to the wall of
the cable tray at the built-in cable tie positions.
8. Behind port carrier B of EPN cabinet 3:
Install a lightwave transceiver on cable connector at slot 3B03.
Connect the other end of the fiber optic cable to the lightwave
transceiver, just installed, at slot 3B03.
Carefully attach the fiber optic cable (with cable ties) to the wall of
the cable tray at the built-in cable tie positions.
At the top of the cabinet, coil the surplus fiber optic cable, and
carefully attach the coil to the wall of the cable tray.