Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
G3vs with Intel 386 or Risc Processor to R8r
4-7Remove the Present System
4
Remove the Present System
If the equipment room is large enough to allow the Release 8r cabinet to
be installed while the present system is in service, skip to
‘‘Install the
Release 8r Cabinets’’ on page 4-11. Return to this section when finished.
If the present system must be removed to make room for the Release 8r
cabinet, perform the following.
Save Translations and Announcements
1. Log in at the management terminal on the present system.
2. Type
save translation
and press
Ent er . This command instructs the system
to write all translation information from memory to the translation card.
3. Check for translation errors before proceeding with the upgrade. If errors
are detected, refer to
‘‘No Translations After Upgrade’’
in
Appendix B,
‘‘Troubleshooting an Upgrade’’ to correct the problem. Do not continue
with the upgrade until the errors are corrected.
4. If the system contains a TN750/B Announcement circuit pack, type
display announcements
and press
Enter.
NOTE:
The TN750C Announcement circuit pack contains non-volatile
memory and does not require backup.
5. If administered recorded announcements are listed, type
save
announcements
and press
Enter.
6. Remove the translation card and install the backup translation card.
Check Link Status
1. Type
display communication-interface links
and press Enter. Write down
all enabled links.
2. Type
status link
number
and press Enter. Repeat this step for all links.
3. Write down which links are in service.