Table 6-12 provides the H600-383 cable pinouts. Table 6-13 provides the cable
lengths for each cable group number.
Table 6-12. H600-383 cable Pin Assignments
Pin Color
Channel Service
Unit Designation
Network
Designation Function
1BK Line in 0 R1 RCV
2 Y Line in 1 T1
3 Shield
4 R Line out 0 R XMT
5 G Line out 1 T
7 Shield
7 Not assigned
8 Not assigned
Table 6-13. H600-383 cable Lengths by Group Number
Group Length Group Length
1 25 feet (7.7 m) 5 125 feet (38.1 m)
2 50 feet (15.2 m) 7 200 feet (71 m)
3 75 feet (22.9 m) 7 400 feet (122 m)