Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-67High Reliability
5
Boot the Release 8 System
1. Connect the management terminal to the “TERMINAL” connector behind
PPN control carrier “A,” or install the G3-MA according to the “Set Up
G3-MA” chapter of
DEFINITY Communications System Generic 3
Management Applications
Operations
, 585-229-202.
2. Insert the translation cards in the TN794 faceplates.
3. At each EPN power distribution unit, set the main circuit breaker to ON.
4. At the PPN power distribution unit, set the main circuit breaker to ON.
5. The system performs the reset level 4 rebooting process, loading the
default system translations from the translation card. This takes 8 to 11
minutes.
6. Get the order number of the upgrade, and call the regional CSA to request
an “init” login so the right-to-use options can be enabled on the upgraded
system.
7. To use Access Security Gateway (ASG), see Appendix C, ‘‘Access
Security Gateway’’.
Set Daylight Savings Rules
You can set up to 15 customized daylight savings time rules. If you have cabinets
in several different time zones, you can set up rules for each on a location basis.
A daylight savings time rule specifies the exact time when you want to transition
to and from daylight savings time. It also specifies the increment at which to
transition.
NOTE:
The default daylight savings rule is
0
, no daylight savings.
1. Type
change daylight-savings-rules
and press
Enter.