Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-60Add IP Interface Assembly
6
Connect the Monitor, Keyboard, and Mouse
NOTE:
Only make these connections if administered locally. Not necessary if
administered remotely.
You must connect these before inserting the TN802B IP Interface.
1. Attach a VGA monitor to the VGA connector of the TN802B IP Interface
external cable assembly.
2. Attach the keyboard to the KEYBOARD connector of the external cable
assembly.
3. Attach the mouse to the MOUSE connector of the external cable
assembly.
4. Plug the monitor into an AC power receptacle and turn it on.
Table 6-7. U.S. Robotics Modem Dip Switch Settings
Dip
Switch Setting Description
1
UP
DOWN
Data Terminal Ready normal
Data Terminal Ready override
2
UP
DOWN
Verbal result codes
Numeric result codes
3
UP
DOWN
Suppress result codes
Display result codes
4
UP
DOWN
Echo offline commands
No echo, offline commands
5
UP
DOWN
Auto answer on first ring or higher if specified in NVRAM
Auto answer off
6
UP
DOWN
Carrier detect normal
Carrier detect override
7
UP
DOWN
Load NVRAM defaults
Load factory defaults
8
UP
DOWN
Dumb mode
Smart mode