Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Fiber Link Administration
A-18Administer Fiber Links
A
Duplicated DS1 Converter Complex Administration for T1 TN1654 Circuit
Packs.
Screen 6-6. Fiber Link Administration form for E1 TN1654 Circuit Pack (DS1 Converter
Complex Administration) (page 2 of 3)
The following unique fields display when administering a TN1654 DS1 Converter.
Bit Rate A display-only field for TN1654 entered on page 3 of the form.
See previous section.
1.544
indicates domestic T1 operation and
2.048
indicates international E1 operation.
DS1 Converter Complex Administration for E1 TN1654 Circuit Packs .
The following unique fields display when administering a E1 TN1654 DS1
Converter.
Bit Rate Displays when the DS1 Converter circuit pack is TN1654.
Enter either
1.544
for domestic T1 operation or
2.048
for international E1
operation.
NOTE:
Since one bit rate applies for all facilities within the same DS1
Converter complex,
Bit Rate
displays only under Facility A. To
activate the desired Bit Rate, the toggle switch on the circuit pack
must be set and it must correspond to the Bit Rate.
Idle Code MSB(1) ... LSB(8) Displays when the DS1 Converter circuit
pack is TN1654. Enter 8 digits, each digit must be
0
or
1
. The second digit
must be
1
. Default is
11101000
. You can administer this field on a per
circuit pack basis.
add fiber-link next Page 2 of 3
FIBER LINK ADMINISTRATION
A-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES
DS1CONV Board Location: 01B01 DS1CONV Board Location: 02B01
DS1CONV Board Type: TN1654 DS1CONV Board Type: TN1654
DS1 CONVERTER FACILITIES
ABC D
Facility Installed? yes yes yes no
Bit Rate: 2.048
Facility Startup Idle Code: 11101000
Line Coding: hdb3 hdb3 hdb3 hdb3
CRC? yes
Line Termination:
Facility A Circuit ID: 09876543
Facility B Circuit ID: 234567889
Facility C Circuit ID: 434566335