DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
G3vs with Intel 386 or Risc Processor to R8r
4-11Install the Release 8r Cabinets
4
Install the Release 8r Cabinets
Unpack and Install the Release 8r Cabinet
1. Refer to the installation instructions in
DEFINITY Enterprise
Communications Server Release 8 Installation and Test for Multicarrier
Cabinets
.
!
CAUTION:
Do not power up the Release 8r system.
2. Return to this section when the installation of the Release 8r is completed.
Remove Emergency Transfer Ground Wire
1. If the Release 8r is being installed while the present system is in service:
a. Connect a 10 AWG (#25) (2.6 mm
2
) wire either to pin 49 of the
connecting block or to pin 49 of the CAP (cable access panel)
associated with the emergency transfer panel.
b. Route the other end of the wire to an approved ground and
connect.
2. If the present system was removed to make room for the Release 8r
cabinet:
a. Disconnect the 10 AWG (#25) (2.6 mm
2
) wire (installed earlier) from
the connecting block or pin 49 of the CAP (cable access panel).
Power-Up the Release 8r
1. Insert the new Release 8r removable media into the optical drive.
2. Power up the Release 8r cabinet and allow the system to boot up
completely.
List Configuration Software Long
1. Type
list configuration software long
and press Enter to verify the
removable media contains the required Release 8 software.
2. Make note of the entire alphanumeric string of the software version. This
information is used later.