Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Fiber Link Administration
A-17Administer Fiber Links
A
DS1 Converter Complex Administration for T1 TN1654 Circuit Packs.
Screen 6-5. Fiber Link Administration form for T1 TN1654 Circuit Pack (DS1 Converter
Complex Administration) (page 2 of 3)
The following unique fields display when administering a T1 TN1654 DS1
Converter.
Bit Rate Displays when the DS1 Converter circuit pack is TN1654.
Enter either
1.544
for domestic T1 operation or
2.048
for international E1
operation.
NOTE:
Since one bit rate applies for all facilities within the same DS1
Converter complex, the
Bit Rate
field displays only under
Facility A.
Facility Startup Idle Code Displays when the DS1 Converter circuit
pack is TN1654. Enter 8 digits, each digit must be
0
or
1
. The second digit
must be
1
. Default is
11101000
. You can administer this field on a per
circuit pack basis. This is the idle code used when a TN1654 first
establishes a link on a T1/E1 facility. The initial idle code used by the
TN1654 is overwritten by the center stage switch to an “all ones” pattern
once framing is established on that T1/E1 facility.
Framing Mode
For TN1654 with 1.544 Mbps Bit Rate, this is a
display-only field.
add fiber-link next Page 2 of 3
FIBER LINK ADMINISTRATION
A-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES
DS1CONV Board Location: 01B01 DS1CONV Board Location: 02B01
DS1CONV Board Type: TN1654 DS1CONV Board Type: TN1654
DS1 CONVERTER FACILITIES
ABC D
Facility Installed? yes yes no no
Bit Rate: 1.544
Facility Startup Idle Code: 11101000
Line Coding: ami-zcs ami-zcs ami-zcs ami-zcs
Framing Mode:
DS1CONV-1 Line Compensation: 1 1 1 1
DS1CONV-2 Line Compensation: 1 1 1 1
Facility A Circuit ID: 09876543
Facility B Circuit ID: 234567889