Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Troubleshooting an Upgrade
B-12Troubleshooting Release 8 Upgrades
B
Software Incompatibility
If these procedures do not clear the corruption problem, then the software
versions may be incompatible. You may need to upgrade to an interim software
version before upgrading to the final software version.
1. Consult the remediation that came with the upgrade software.
2. Contact your Lucent Technologies representative for this information.
Re-install the ISDN-PRI Links (Only for Failed
Upgrades)
If your upgrade failed and you need to re-install the ISDN-PRI links, use this
procedure.
1. Type
add data-module [PI ext]
and press
Enter.
2. Type the information in the fields based on the information that you
entered earlier.
3. Type
change communication-interface links
and press
Enter.
4. Type the information in the fields based on the information that you
entered earlier with one exception. Leave the
Enable
field setting as it is.
5. Type
change communication-interface processor-channels
and press
Enter.
6. Type the information in the fields based on the information that you
entered earlier.
7. Type
change communication-interface links
and press
Enter.
8. Type the information in the
Enable
field based on the information that you
entered earlier.
9. Type
save translation
and press
Enter.