DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-93Add a Control Carrier (Add Duplication)
6
Restart DEFINITY LAN Gateway System
1. Log onto the DEFINITY LAN Gateway.
2. When the main menu appears, select
Maintenance
.
3. Select
Reset System
from the
Maintenance
menu.
4. Select
Restart System
from the
Reset System
menu.
Enable SPE Duplication
1. If not also duplicating switch node carriers, refer to Duplication-Related
System Parameters in
DEFINITY Enterprise Communications Server
Release 8 Administrator’s Guide
, to enable Switch Processing Element
(SPE) duplication.
Enable PNC Duplication
1. For a critical-reliability R8r system, type
change system-parameters
customer-options
and press
Enter. Use this screen to enable the Port
Network Connectivity (PNC) duplication option.
Resolve Alarms and Enable Alarm Origination
1. Examine the alarm log. Resolve any alarms using
DEFINITY Enterprise
Communications Server Release 8 Maintenance for R8r
.
2. If the
Alarm Origination Activated
field administration is already
set to
y
, be sure to enable Alarm Origination. Otherwise you do not need to
enable Alarm Origination (proceed to the next section).
3. Type
change system-parameters maintenance
and press
Enter.
The
Alarm Origination Activated
field was changed to
Alarm
Origination to OSS Numbers
to support more than 1 OSS.
4. Type
first-only
in this field to enable Alarm Origination (to the first OSS,
which should be INADS).
Be sure to enter
y
in both
Cleared Alarm Notification
and
Restart Notification
fields. Press
Enter.
5. Type
save translation spe-a disk
and press
Enter.
NOTE:
The INADS Database Administrator enables Alarm Origination as part of
the registration process.
!
WARNING:
If you do not enable Alarm Origination when the customer has purchased a
services contract, the switch will not report any alarm to the TSC
automatically, causing the TSC to be unable to fulfill the services contract.