Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-52High Reliability
5
9. Connect the remaining end of the TDM/LAN cable (between the “A” and
“D” carriers) to the pin-field block marked “TDM” on the right side of the
“A” carrier. See
Figure 5-13
and
Table 5-11
. The other end remained
connected to the “D” carrier when the old carrier was removed.
10. Connect the remaining end of the TDM/LAN cable (between the “A” and
“C” carriers) to the pin-field block marked “TDM” on the left side of the “A”
carrier. The other end remained connected to the “C” carrier when the old
carrier was removed.
11. On port carrier J58890BB-1, connect the TDM cable or TDM terminator to
Slot 02. On port carriers J58890BB-2 and J58890BB-3, connect the TDM
cables to Slot 01.