Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
G3vs with Intel 386 or Risc Processor to R8r
4-8Remove the Present System
4
Disable TTI
!
CAUTION:
If you do not disable the TTI, the translations can be corrupted.
1. Make sure the ISDN is in service. If not, attempt to busy out and release
the ISDN D-channel/link. This will bring the ISDN trunks back into service.
2. Type
change system-parameters features
and press
Enter.
3. On the second screen, set the
Enabled?
field to
n
to de-activate the TTI
feature.
Disable Alarm Origination to INADS
1. Type
change system-parameters maintenance
and press Enter.
2. Type
neither
in the
Alarm Origination to OSS Numbers
field.
3. For some releases of software, disable
Cleared Alarm Notification
and
Restart Notification
field before submitting the form.
!
CAUTION:
If Alarm Origination is not disabled, the system may generate alarms,
resulting in unnecessary trouble tickets.
Shut Down DEFINITY LAN Gateway System
!
WARNING:
Neglecting to shut down a DEFINITY LAN Gateway assembly before
powering down the system cabinet can damage the LAN Gateway disk.
1. Log onto the DEFINITY LAN Gateway. See
DEFINITY Communications
System Generic 3 Installation, Administration and Maintenance of
CallVisor ASAI over the DEFINITY LAN Gateway
for the procedure to log
on.
2. When the main menu appears, select
Maintenance
.
3. Select
Reset System
from the
Maintenance
menu.
4. Select
Shutdown
from the
Reset System
menu.
5. Unseat the LAN Gateway assembly from its backplane connectors.