DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-116Add a Switch Node Carrier (High or Critical Reliability)
6
9. Also, for the PPN, connect the loose end of the TDM/LAN cable (between
the “A” and “D” carriers) to the other pin-field block marked “TDM/LAN” on
the right side of the “D” carrier. See
Figure 6-41
and
Table 6-10
. The other
end remained connected to the “A” carrier when the old carrier was
removed.
Figure 6-41. TDM/LAN Connections for Critical Reliability R8r EPN
J58890SA-1
J58890BB
B POSITION
J58890AF-1
SLOT 21
SEE NOTE
SLOT 01
PORT CARRIER
SWITCH NODE CARRIER
D POSITION
A POSITION
SLOT 21
PORT CARRIER
TDM/LAN BUS TERMINATOR
(ZAHF4)
J58890BB
SLOT 21
C POSITION
TDM/LAN BUS
TERMINATOR
(ZAHF4)
SLOT 01
REAR VIEW
E POSITION
SWITCH NODE CARRIER
J58890SA-1
NOTE:
ON PORT CARRIER J68890BB-1, CONNECT TDM/LAN CABLE OR TDM/LAN TERMINATOR TO SLOT 02.
ON PORT CARRIERS J58890BB-2 AND -3, CONNECT THE TDM/LAN CABLE OR TDM/LAN TERMINATOR
TO SLOT 1.
EXPANSION
CONTROL
CARRIER
ICCB
ICCB
ICCA
SEE NOTE
ICCA
INTERCARRIER
CABLES A AND B
H600-204 G1
TDM/LAN CABLE
WP91716 L6
TDM/LAN CABLE
WP91716 L6