DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-55Add IP Interface Assembly
6
.
Test the External Connection to the LAN
To test the external IP connections, ping the IP Interface server, and ping a
known computer connected to your network. If everything is configured correctly,
the
Result
column on the Ping Results screen reads
pass
. If it reads
abort
,
verify the IP-address information and check the connectivity, including the
cabling.
1. Type
ping ip-address
nnn.nnn.nnn.nnn
board
UUCSS
and press Enter.
The variable
nnn.nnn.nnn.nnn
is the IP address of the TN802B IP
Interface and
UUCSS
is the cabinet, carrier, and slot of the TN802B IP
Interface.
2. Type
ping ip-address
nnn.nnn.nnn.nnn
board
UUCSS
and press Enter.
The variable
nnn.nnn.nnn.nnn
is the IP address of the customer’s
gateway and
UUCSS
is the cabinet, carrier, and slot of the TN802B IP
Interface.
change ip-interfaces Page 1 of 2
Network regions are interconnected? n
En- Net
abled Type Slot Code Sfx Node Name Subnet Mask Bcast/Gway
Addr Rgn
n C-LAN 01A09 TN799 clan-a1 255.255.255.0 192.168.1 .100 1
y MEDPRO 01A13 TN802 B med-a1 255.255.255.0 192.168.1 .21 1
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
ping ip-address 192.168.10.21
PING RESULTS
End-pt IP Port Port Type Result Time(ms) Error Code
192.168.10.21 01A13 MEDPRO PASS 10 1124