HP (Hewlett-Packard) B Network Router User Manual


 
Example Setup to arm only when the signal on channel 2 falls through -0.48 volts.
ARM:SOUR1 INT2 Set arming source 1 to arm when the
specified level is met on channel 2
ARM:SLOP1 NEG The signal must fall through the level set by
ARM:LEVel2:NEG for arming to occur
ARM:LEV2:NEG -0.48 Arm when the signal passes through the
-.48V level
[:STARt]:LEVel[<
chan
>]:POSitive <
voltage
>
ARM[:STARt]:LEVel[<chan>]:POSitive <voltage> selects the input voltage
level which will arm a measurement cycle. The ARM:LEVel:POSitive setting is
used only when either of the ARM:STARt:SOURce(s) is set to INTernal1 or
INTernal2, and the corresponding ARM:STARt:SLOPe<n> setting is POSitive or
EITHer. The value programmed is retained (but not used) when other sources are
selected, or when the corresponding ARM:STARt:SLOPe<n> setting is NEGative.
The allowable levels depend on the measurement range as set by the
SENSe:VOLTage:RANGe command.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
chan
numeric 1 | 2 none
level
numeric -102.2418 to 102.2418
MINimum | MAXimum
Volts
Comments Executable while initiated: No
Coupled Command: Yes. The command is coupled to the
ARM[:STARt]:SLOPe, ARM[:STARt]:SOURce, and SENSe:VOLTage:RANGe
commands. The level value is limited to the range limits.
ARM[:STARt]:LEVel[<
chan
>]:POSitive <
voltage
>
ARM Subsystem Command Reference 193