HP (Hewlett-Packard) B Network Router User Manual


 
Subsystem Commands Description
ARM ARM[:STARt]:COUNt <
count
>
ARM[:STARt]:DELay <
period
>
ARM[:STARt][:IMMediate]
ARM[:STARt]:LEVel[<cha
n
>]:NEGative <
voltage
>
ARM[:STARt]:LEVel[<
chan
>]:POSitive <
voltage
>
ARM[:STARt]:SLOPe[<
n
>] <
edge
>
ARM[:STARt]:SOURce[<
n
>] <
source
>
Specifies the number of measurement
cycles (bursts) to occur.
Delay from when the digitizer is armed to
when it enters the wait-for- trigger state.
Places the digitizer in the wait-for-trigger
state, independent of the selected
ARM:STARt:SOURce.
Selects the (negative-going) signal level
which arms the digitizer.
Selects the (positive-going) signal level
which arms the digitizer.
Selects the edge: positive, negative, or
either, which will arm the digitizer.
Sets the digitizer arm source.
CALibration CALibration[<
chan
>]:COUNt?
CALibration[<
chan
>]:DATA <
block_data
>
CALibration[<
chan
>]:DELay
CALibration[<
chan
>]:GAIN [<
readings
>
[,<
period
>[,<
flag
>]]]
CALibration[<
chan
>]:SECure:CODE <
code
>
CALibration[<
chan
>]:SECure:STATe <
mode
> [,<
code
>]
CALibration[<
chan
>]:STORe
CALibration[<
chan
>]:STORe:AUTO <
mode
>
CALibration[<
chan
>]:VALue <
number
>
CALibration[<
chan
>]:ZERO [<
readings
>
[,<
period
>,[<
mode
>]]]
Returns a number that indicates how often
the digitizer has been calibrated.
Manually sets or queries the calibration
constants.
Calibrates the A/D converter delay constant.
Performs a gain calibration using the
specified number of readings and sample
rate.
Sets the code required to disable
calibration security.
Enables/disables calibration security.
Stores the currently selected channel’s
calibration constants into non-volatile
memory.
Selects whether or not calibration constants
will be automatically stored.
Specifies the voltage level at the input.
Performs a calibration of the zero offset.
CONFigure CONFigure[<
chan
>]:ARRay[:VOLTage][:DC] (<
size
>)
[,<
expected value
>[,<
resolution
>]]
[,(@<
input port
>)]
Configures the digitizer for <size> number
of readings on the specified channel and
input port.
DIAGnostic DIAGnostic:CALibration[<
chan
>]:CONVerge?
DIAGnostic:CALibration[<
chan
>]:GAIN:SENSitivity?
DIAGnostic:CALibration[<
chan
>]:ZERO:SENSitivity?
DIAGnostic:CHANnel[<
chan
>]:LABel <
label
>
Returns convergence data from the latest
CAL:ZERO or CAL:GAIN.
Returns the sensitivity constant used during
the last CAL:GAIN command.
Returns the sensitivity constant used during
the last CAL:ZERO command.
Sets the bit pattern (label) specified on the
four least significant bits of the reading.
Table 4-1. HP E1429A/B Command Quick Reference.
310 Command Quick Reference Chapter 4