HP (Hewlett-Packard) B Network Router User Manual


 
Maximum Gain
Calibration Values (V)
Voltage Range
(Volts)
Allowable
Ports
-.10180 and .10185 0.10235 1,2,3,4
-.2036 and .2037 0.2047 1,2,3,4
-.5090 and .50925 0.51175 1,2,3,4
-1.0180 and 1.0185 1.0235 1,2,3,4
-2.036 and 2.037 2.037 3,4
-5.090 and 5.0925 5.1175 3,4
-10.180 and 10.185 10.235 3,4
-20.360 and 20.370 20.37 3,4
-50.900 and 50.925 51.175 3,4
-101.80 and 101.85 102.35 3,4
< -48.925 and > 48.975 102.35 3,4
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
number
numeric -101.80 to 101.85 volts
Comments Executable when initiated: No
Coupled Command: No
Calibration values on the 102.35 volt range have a special low end allowed, so
that voltages much less than full scale may be used to calibrate gain on this range.
Values < -48.975 and > 48.975 are accepted as legal values for calibrating the
102.35 volt range.
CALibration:VALues used for GAIN calibration are at least 85% of full scale and
10 counts away from absolute full scale. The previous table lists the gain
calibration values.
Related commands: CALibration:GAIN
*RST Condition: CALibration<chan >:VALue 1.0185
CALibration[<
chan
>]:VALue
CALibration[<
chan
>] Subsystem Command Reference 209