HP (Hewlett-Packard) B Network Router User Manual


 
Currents in Amps (typical) E1429A E1429B
+5V : I(pm) 2.9 3.1
I(dm) 0.5 0.5
+12V : I(pm) 0.2 0.2
I(dm) 0.04 0.04
- 12V : I(pm) 0.2 0.2
I(dm) 0.04 0.04
+24V : I(pm) 0.1 0.1
I(dm) 0.05 0.05
-24V : I(pm) 0.1 0.1
I(dm) 0.05 0.05
-5.2V : I(pm) 3.6 4.1
I(dm) 0.36 0.36
-2V : I(pm) 1.2 1.3
I(dm) 0.12 0.12
+5VS : I(pm) 0 0
I(dm) 0 0
Typical Watts/Slot: 41.5 45.3
dPressure (H2O): 0.8 mm
AirFlow (liters/s):3.8
EMC: To meet EMC requirements in Europe, a backplane connector
shield kit is included.
Built-In Test : Extensive built-in test checks memory, timebase, much of
the trigger system, and part of the analog signal path.
Notes pertaining to IEEE 1057:
1057-1:
Based on Code Transition Levels per 4.1.2 except that levels -2047
and -2046 are not included in this characterization. The minimum
code transition level characterized is (from -2046 to) -2045; the maximum
is (from +2046 to) +2047.
Appendix A Specifications 329