HP (Hewlett-Packard) B Network Router User Manual


 
[SENSe[<
chan
>]]:VOLTage[:DC]
The SENSe:VOLTage[:DC] commands select the voltage range, and report back the
resolution associated with the selected range.
Subsystem
Syntax
[SENSe[<
chan
>]]
:VOLTage
[:DC]
:RANGe <
range
>
:RESolution? [query only]
:RANGe
[SENSe[<chan >]]:VOLTage[:DC]:RANGe <range > selects the range for
voltage measurement on the specified channel.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
chan
numeric 1|2 none
range
numeric -102.30 to 102.35 |
MINimum | MAXimum
volts
The various range settings are given in the following table, along with the input
ports supported on each range, and the measurement range spanned by the given
range.
262 Command Reference [SENSe[<
chan