HP (Hewlett-Packard) B Network Router User Manual


 
[SENSe[<
chan
>]]:FUNCtion
The SENSe:FUNCtion commands select which of the input ports gets connected to
a particular channel. SENSe1 selects the input for the sensor on channel 1 (ports 1
or 3), and SENSe2 selects the input for the sensor on channel 2 (ports 2 or 4).
Subsystem
Syntax
[SENSe[<
chan
>]]
:FUNCtion "<
function
>"
[SENSe[<
chan
>]]:FUNCtion
[SENSe[<chan>]]:FUNCtion "<function>" determines which input port will be
connected to the specified sensing channel. Each sense channel has two input ports;
one port is single ended and the other is differential. Odd numbered ports (1 and 3)
connect to channel 1, and the even numbered ports (2 and 4) connect to channel 2.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
chan
numeric 1|2 none
function
quoted
string
"VOLTage[:DC]1" |
"VOLTage[:DC]2" |
"VOLTage[:DC]3" |
"VOLTage[:DC]4"
none
Comments Executable when initiated: No
Coupled Command: Yes. This command is coupled to
SENSe:VOLTage:DC:RANGe, ARM:STARt:LEVel:NEGative, and
ARM:STARt:LEVel:POSitive.
Function choices ending in 1 and 3 ("VOLTage:DC1" or "VOLTage:DC3") are
the only choices for channel 1 (SENSe1:FUNCtion). Function choices ending in 2
and 4 ("VOLTage:DC2" or "VOLTage:DC4") are the only legal choices for
channel 2 (SENSe2:FUNCtion). Specifying an illegal function choice on a sense
channel will result in error -151, "Invalid string data".
Related Commands: SENSe:VOLTage:DC:RANGe,
ARM:STARt:LEVel:NEGative, ARM:STARt:LEVel:POSitive
252 Command Reference [SENSe[<
chan