ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
Utility Commands 6-36
v1.0, November 2010
no sntp unicast client poll-retry
This command will reset the poll retry for SNTP unicast clients to its default value.
sntp server
This command configures an SNTP server (a maximum of three). The optional priority can be a
value of 1-3, the version a value of 1-4, and the port id a value of 1-65535.
no sntp server
This command deletes an server from the configured SNTP servers.
clock timezone
When using SNTP/NTP time servers to update the switch’s clock, the time data received from the
server is based on Coordinated Universal Time (UTC) which is the same as Greenwich Mean
Time (GMT). This may not be the time zone in which the switch is located. Use the clock
timezone command to configure a time zone specifying the number of hours and optionally the
number of minutes difference from UTC. To set the switch clock to UTC, use the no form of the
command.
Format sntp unicast client poll-retry <poll-retry>
Mode Global Config
Format no sntp unicast client poll-retry
Mode Global Config
Format sntp server <ipaddress|ipv6address| hostname> [<priority> [<version>
[<portid>]]]
Mode Global Config
Format no sntp server remove <ipaddress|ipv6address| hostname>
Mode Global Config
Format clock timezone zone-name +/-hours-offset [+/-minutes-offset]