NETGEAR XSM7224S-100NAS Switch User Manual


 
ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
Management Commands 7-10
v1.0, November 2010
enable authentication
To specify authentication method list when the user accesses a higher privilege level in remote
telnet or console, use the
enable authentication command in line configuration mode.
no enable authentication
To return to the default specified by the
enable authentication command.
show serial
This command displays serial communication settings for the switch.
Format enable authentication {default | list-name}
Mode Line Config
Format no enable authentication {default | list-name}
Mode Line Config
Format show serial
Modes Privileged EXEC
User EXEC
Term Definition
Serial Port Login
Timeout
(minutes)
The time, in minutes, of inactivity on a Serial port connection, after which the Switch will
close the connection. Any numeric value between 0 and 160 is allowed, the factory default
is 5. A value of 0 disables the timeout.
Baud Rate (bps) The default baud rate at which the serial port will try to connect. The available values are
1200, 2400, 4800, 9600, 19200, 38400,57600, and 115200 baud. The factory default is
9600 baud.
Character Size
(bits)
The number of bits in a character. The number of bits is always 8.
Flow Control Whether Hardware Flow-Control is enabled or disabled. Hardware Flow Control is always
disabled.
Stop Bits The number of Stop bits per character. The number of Stop bits is always 1.
Parity Type The Parity Method used on the Serial Port. The Parity Method is always None.