vlan
This command creates a new VLAN and assigns it an ID. The ID is a valid VLAN identification
number (ID 1 is reserved for the default VLAN). The vlan-list contains VlanId's in range <1-
4093>. Separate non-consecutive IDs with ',' and no spaces and no zeros in between the range; Use
'-' for range.
no vlan
This command deletes an existing VLAN. The ID is a valid VLAN identification number (ID 1 is
reserved for the default VLAN). The vlan-list contains VlanId's in range <1-4093>. Separate non-
consecutive IDs with ',' and no spaces and no zeros in between the range; Use '-' for range.
vlan acceptframe
This command sets the frame acceptance mode per interface. For VLAN Only mode, untagged
frames or priority frames received on this interface are discarded. For Admit All mode, untagged
frames or priority frames received on this interface are accepted and assigned the value of the
interface VLAN ID for this port. With either option, VLAN tagged frames are forwarded in
accordance with the IEEE 802.1Q VLAN Specification.
Format vlan <vlan-list>
Mode VLAN Config
Format no vlan <vlan-list>
Mode VLAN Config
Default all
Format vlan acceptframe {vlanonly | all}
Mode Interface Config