Fujitsu DX8100 S2 Computer Drive User Manual


  Open as PDF
of 1066
 
Chapter 6 RAID Group Management
6.2 Functions in the Action Area for RAID Group
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
187
The procedure to expand RAID group capacity is as follows:
Procedure
1 Select the RAID group that is to be expanded and click [Expand] in [Action].
2 Select the RAID type after expansion and the drives that are to be used after expansion.
Click the [Expand] button.
RAID Type after expand
Select the RAID type after expansion is performed.
- High Performance (RAID1+0)
- High Capacity (RAID5)
- High Reliability (RAID6)
- Striping (RAID0)
Checkbox to select drives
Select the checkbox for the drive to be used.
When using the ETERNUS DX8100 S2/DX8700 S2, the restrictions that apply to the drive layout for
RAID group configuration vary depending on the RAID type. Refer to "Restrictions of drive layout"
(page 179) for details.
The following functions cannot be used for RAID groups in which RAID group expansion is being
performed:
- Format volume
- Create Volume
- Encrypt Volume
- RAID migration for the volume
- Expand Volume
- Preventive maintenance
- Diagnosis for RAID group
- Diagnosis for disks
The following RAID type changes cannot be performed:
- Changing the RAID type to "Striping (RAID0)" (changing the RAID type from "Striping (RAID0)" to a dif-
ferently configured "Striping (RAID0)" is available)
- Changing the RAID type to "Reliability (RAID5+0)"
- Changing the RAID type from "Reliability (RAID5+0)"
When expanding the drive capacity that configures a RAID group, use the procedure in "5.2.7 Start RAID
Migration" (page 123) instead of this function.