Chapter 9 Connectivity Management
9.2 Functions in the Action Area for Connectivity
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
546
Alias Name
Input the Alias Name of the target port.
While the iSCSI name is a formal nomenclature that specifies the target iSCSI port, an Alias Name is
used as nickname.
An Alias Name that is the same as another port cannot be specified.
The following input condition applies:
- Up to 31 alphanumeric characters
General Settings
Jumbo Frame
Select whether to "Enable" or "Disable" the Jumbo Frame.
Select "Enable" when using the Jumbo Frame to transfer data via the target port. When not using
the Jumbo Frame, select "Disable".
Enabling Jumbo Frame increases the amount of data to be transferred per Frame, making data
transfer more efficient.
Confirm that the connected device (*1) supports the Jumbo Frame before enabling the Jumbo
Frame.
*1: When the ETERNUS DX Disk storage system and server are connected directly, this indicates that the
connected device is a server side LAN card (NIC). When the ETERNUS DX Disk storage system and server
are connected via a switch, this indicates that the connected device is a switch.
VLAN ID
Select whether to "Enable" or "Disable" the VLAN ID for the target port.
When "Enable" is selected, specify the VLAN ID between 0 and 4095.
Reset Scope
Specify the reset scope of the target port.
Reset scope is the range where the command reset from the server is performed, when the target
port is connected to multiple servers.
- I_T_L (I: Initiator, T: Target, L: LUN)
Reset (cancel) the command request from the server that sent the command reset request.
- T_L (T: Target, L: LUN)
Reset (cancels) the command request from all of the servers that are connected to the port.
Release Reservation if Chip is Reset
Select whether to "Enable" or "Disable" the function to release the reserved status of the volume
when the target port (chip) is reset.
The same iSCSI name cannot be set to multiple iSCSI ports except the iSCSI name of the ETERNUS
DX Disk storage system.
When specifying the VLAN ID, confirm the VLAN setting values of the LAN switch and the VLAN
tagging configuration of the server LAN card.