Fujitsu DX8100 S2 Computer Drive User Manual


  Open as PDF
of 1066
 
Chapter 9 Connectivity Management
9.1 Connectivity Status
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
398
IOPS
The performance information from when performance monitoring is started until performance monitoring
is ended (or performance information is displayed) is displayed.
- Ave
The average I/O count per second is displayed.
- Min
The minimum I/O count per second is displayed.
- Max
The maximum I/O count per second is displayed.
Throughput
The transfer data size from when performance monitoring is started until performance monitoring is ended
(or performance information is displayed) is displayed.
- Ave
The average data transfer size per second is displayed.
- Min
The minimum data transfer size per second is displayed.
- Max
The maximum data transfer size per second is displayed.
Delay Time
- Total
The total delay time for executing a command from when performance monitoring is started until per-
formance monitoring is ended (or performance information is displayed) is displayed. If the total delay
time exceeds the maximum value, "Overflow" is displayed.
- Ave
The average delay time per command from when performance monitoring is started until performance
monitoring is ended (or performance information is displayed) is displayed.
9.1.8.7 iSCSI Port QoS
This function displays the bandwidth limit and the performance information of the iSCSI ports that are
registered in the ETERNUS DX Disk storage system.
If performance monitoring is restarted during an active performance monitoring session, the
performance information that is already obtained is deleted and the collection of performance
information starts again.
The ports with "CA" or "CA/RA" as the port mode that are registered by the ETERNUS DX Disk storage
system are displayed regardless of whether the ports belong to CA port groups or not.
This function displays the performance information that is obtained during performance monitoring
regardless of whether the Host-LU QoS mode is enabled or disabled. When the performance information
is displayed before performance monitoring is stopped, the performance information that was obtained
up to this point is displayed. This function displays the performance information of each port.