Chapter 9 Connectivity Management
9.2 Functions in the Action Area for Connectivity
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
554
■ When the port mode is "CA/RA"
When the type is "1G iSCSI" or "10G iSCSI" and the port mode is "CA/RA", specify the following items:
● Select Port
• Port
Select the target port.
The selectable port locations are displayed as options:
- CM#x CA#y Port#z (x: CM number, y: CA number, z: Port number)
● TCP/IP Settings
• IP Version
Select the IP version for the target port.
- IPv4
Specify the IPv4 address. When "IPv4" is selected, input "IP Address" (required), "Subnet Mask"
(required), and "Gateway".
- IPv6
Specify the IPv6 address. When "IPv6" is selected, input "IPv6 Link Local Address" (required),
"IPv6 Connect IP Address", and "IPv6 Gateway".
- IPv4 / IPv6
Specify both the IPv4 address and the IPv6 address. The input items for IPv4 and IPv6 can be
specified.
• IP Address
Input the IPv4 address of the target port (required when "IPv4" is selected).
Click the [Test Connection (ping)] button to display the "[Send Ping Command] Screen" (page 565)
.
Specify the IP address to check the connection status of the connection destination storage system
and the number of transmissions. Click the [Send] button. When the "ping" command is sent, the
settings of the IP address and the connection path for the destination storage system can be
checked.
The following input conditions apply:
- Up to 3 numeric characters
- First text box: "1" - "255"
- Other text boxes: "0" - "255"
• Subnet Mask
Input the subnet mask of the target port (required when "IPv4" is selected).
The following input conditions apply:
- Up to 3 numeric characters
- All text boxes: "0" - "255"
• Gateway
Input the gateway IPv4 address of the target port.
- Up to 3 numeric characters
- All text boxes: "0" - "255"