Chapter 5 Volume Management
5.1 Volume Status
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
83
Filter setting
5.1.6 Pinned Data
Volumes including pinned data are displayed.
"Pinned data" is the data left in the cache memory due to unsuccessful write-back to the volume from the
cache memory.
Filter Description
Name
Input the volume name that is to be displayed.
When not using the volume name for filtering, leave this item blank.
LUN Group
Input the LUN group name or the port location information that is to be displayed.
When not using the LUN group name or port location information for filtering, leave this
item blank.
Bottom of Registrant Count
Input the minimum number of reservation keys for the volume that is to be displayed.
When not using the bottom of the registrant count, leave this item blank.
Reservation Type Select the reservation type that is to be displayed.
Reservation Status Select the status of reservations that is to be displayed.
APTPL Select the APTPL that is to be displayed.
When a system message that indicates the detection of pinned data is displayed in the [Overview] screen, or
when a "Pinned data" event is notified by Host Sense or SNMP Trap, use this function to check the detected
pinned data.
Use the [Setup Event Notification] function to specify whether to perform event notification when pinned
data is detected. Refer to "11.2.9.1 Setup Event Notification" (page 880)
for details. Note that writing back,
deleting, and saving pinned data can be performed by a maintenance engineer who has the "Maintenance
Operation" policy.