Fujitsu DX8100 S2 Computer Drive User Manual


  Open as PDF
of 1066
 
Chapter 9 Connectivity Management
9.2 Functions in the Action Area for Connectivity
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
566
A confirmation screen appears.
An error screen appears in the following conditions:
When "IP Address" and "Subnet Mask" for IPv4 are not specified
When "IPv6 Link Local Address" for IPv6 is not specified
When there are parameters that do not satisfy the input conditions
When "255.255.255.255" is input for the IP address, the subnet mask, or the gateway
When the IP address and the network address are the same
When the IP address and the broadcast address are the same
When the gateway is set and the IP address and the gateway are the same
When the gateway is set and the IP Address and the gateway are not in the same subnet
When the [Discovery] button is clicked for "IPv6 Connect IP Address", the IPv6 connect IP address
can be created automatically from the prefix value that is obtained from the router that is
connected to the ETERNUS DX Disk storage system and the input IPv6 link local address.
When the [Discovery] button is clicked for "IPv6 Gateway", the gateway information can be
obtained from the connected router.
To check whether the IP address is allocated correctly and the connection status for the destination
storage system, click the [Test Connection (ping)] button for "IP Address", "IPv6 Link Local
Address", or "IPv6 Connect IP Address".