Chapter 7 Thin Provisioning Pool Management
7.1 Thin Provisioning Pool Status
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
208
The following items are displayed in the Main area:
• No.
The FTRP number is displayed. Click this item to display the screen shown in "7.1.7 Flexible Tier Pool Detail
(Basic)" (page 212).
- ETERNUS DX80 S2/DX90 S2: 0 - 29
- ETERNUS DX410 S2: 0 - 59
- ETERNUS DX440 S2: 0 - 63
- ETERNUS DX8100 S2: 0 - 11
- ETERNUS DX8700 S2: 0 - 63
• Name
The FTRP name is displayed. Click this item to display the screen shown in "7.1.7 Flexible Tier Pool Detail
(Basic)" (page 212).
• Status
The FTRP status is displayed. Refer to "B.4 Thin Provisioning Pool Status" (page 976)
for detailed
information of FTRP status.
• Used Status
The usage of FTRP is displayed.
- Normal
FTRP usage does not exceed the "Attention" threshold.
- Attention
FTRP usage exceeds the "Attention" threshold but does not exceed the "Warning" threshold.
- Warning
FTRP usage exceeds the "Warning" threshold.
• Total Capacity
The total capacity of FTRP is displayed.
• Used Capacity
The used capacity of FTRP is displayed.
• Warning
The warning threshold (%) for monitoring the FTRP used capacity is displayed.
• Attention
The attention threshold (%) for monitoring the FTRP used capacity is displayed. When the "Attention"
threshold is omitted, "0%" is displayed.
• Encryption
The FTRP encryption status is displayed.
- CM
The FTRP that is encrypted by CM.
- "-" (hyphen)