Chapter 10 Component Management
10.1 Component Status
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
685
■ Sensor Information
The real time and threshold values (Low/High) for the temperature, voltage, current, transmission
power, and received power are displayed in the Sensor Information.
When the information cannot be obtained, a "-" (hyphen) is displayed.
The target components for this information are FC that have SFPs from which information can be
obtained.
- Temperature
• Present
The real time temperature of the SFP in the port is displayed.
- x C / y F (x: -128.00 to 128.00, y: -198.40 to 262.40)
• Warning
- Low or High
The Warning threshold (Low/High) for the temperature of the SFP in the port is displayed.
• x C / y F (x: -128.00 to 128.00, y: -198.40 to 262.40)
• Alarm
- Low or High
The Alarm threshold (Low/High) for the temperature of the SFP in the port is displayed.
• x C / y F (x: -128.00 to 128.00, y: -198.40 to 262.40)
- Voltage
• Present
The real time voltage of the SFP in the port is displayed.
- x V (x: 0.00 to 6.55)
• Warning
- Low or High
The Warning threshold (Low/High) for the voltage of the SFP in the port is displayed.
• x V (x: 0.00 to 6.55)
• Alarm
- Low or High
The Alarm threshold (Low/High) for the voltage of the SFP in the port is displayed.
• x V (x: 0.00 to 6.55)
• An SFP is regarded as being in Warning status when the real time value is lower than the Warning
threshold (Low) and higher than the Alarm threshold (Low).
• An SFP is regarded as being in Warning status when the real time value is higher than the Warning
threshold (High) and lower than the Alarm threshold (High).
• An SFP is regarded as being in Alarm status when the real time value is lower than the Alarm
threshold (Low) or higher than the Alarm threshold (High).