Chapter 9 Connectivity Management
9.2 Functions in the Action Area for Connectivity
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
524
→ A confirmation screen appears.
3 Click the [OK] button.
→ Registration of the SAS port group starts.
An error screen appears in the following conditions:
• When the port group name does not satisfy the input conditions
• When the port group name has not been entered
An error screen appears in the following conditions:
• When the port group name overlaps with an existing port group name (port group names cannot
overlap with any other port group names, irrespective of the CA types)
• When the total number of ports has exceeded the maximum number for the ETERNUS DX Disk
storage system
• When no ports are registered in a port group, or when nine or more ports are registered in a port
group
• When the specified port does not exist in the ETERNUS DX Disk storage system
• When the port mode of the selected port is other than "SAS"
• When there are ports of which affinity mode is enabled ("ON") and disabled ("OFF") existing
together