Lucent Technologies Release 8.2 Server User Manual


 
Configuration 2: R7r (+CMS) <—ethernet—> R7csi 3 C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
90
Switch 2 Task— Assign Processor Channels
This task associates data links (hardware) with processor channels (software) on
Switch 2.
Begin
Steps
> Open the Processor Channel Assignment form — enter ch com p
> Enter values
change communications-interface processor-channels
Page 1 of X
PROCESSOR CHANNEL ASSIGNMENT
Proc Gtwy Interface Destination Session Mach
Chan Enable Appl. To Mode Link/Chan Node Port Local/Remote ID
1: y
mis____ s 5_ 5001__ node-2____ 0____ 1 _1__ __
2: n
_______ _ __ _____ __________ 0____ ___ ___ __
3: n _______ _ __ _____ __________ 0____ ___ ___ __
4: n
_______ _ __ _____ __________ 0____ ___ ___ __
:
21: y
dcs ___ c 5_ 0 node-1____ 5003_ 21_ 12_ 1_
:
64: n
_______ _ __ _____ __________ 0____ ___ ___ __
Field Conditions/Comments
Processor Channel 1: (connection to CMS)
Enable Set to y.
Appl. Enter mis for the CMS connection on Processor Channel 1.
Mode Set the Mode to s (“server”) on both switches for connections
to CMS.
Interface Link This must match the link number assigned on the node-5 data
module screen on this switch.
Interface Chan For TCP/IP, interface channel numbers are in the range 5000
– 64500.
The recommended values are: 5001 for CMS, 5002 for Intuity
AUDIX, and 5003 for DCS connections that are not gateways.
These three values should be reused for multiple instances of
these applications; for example, if there are two Intuity
AUDIX’s, use 5002 for both; or if there are four DEFINITY
ECS’s, use 5003 for all four. The combination of Link,
Interface Channel, and Mach ID must be unique.
The recommended values for gateway switches is 6001–6099.
The interface channel number must be unique for each
gateway.
1 of 3