Lucent Technologies Release 8.2 Server User Manual


 
Switch-Node 1 Administration 4 Networking Example
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
208
Switch-Node 1 Administration
This section displays the filled-in screens for the administration of Switch Node 1.
DS1 Circuit Packs
Connection to Switch
Node 2
Connection to Switch
Node 3
add ds1 1c19 Page 1 of 2
DS1 CIRCUIT PACK
Location: 01c19 Name: Switch 1 to Switch 2
Bit Rate: 1.544 Line Coding: b8zs
Line Compensation: 1
Framing Mode: esf
Signaling Mode: common-chan
Interface Companding: mulaw
Idle Code: 11111111
DMI-BOS? n
Slip Detection? n Near-end CSU Type: other
add ds1 1c18 Page 1 of 2
DS1 CIRCUIT PACK
Location: 01c18 Name: Switch 1 to Switch 3
Bit Rate: 1.544 Line Coding: b8zs
Line Compensation: 1
Framing Mode: esf
Signaling Mode: isdn-pri
Connect: pbx ____ Interface: network
Country Protocol: 1
Protocol Version: a
Interface Companding: mulaw
CRC? n
Idle Code: 11111111
DCP/Analog Bearer Capability: 3.1kHz
Slip Detection? n Near-end CSU Type: other