Lucent Technologies Release 8.2 Server User Manual


 
H.323 Trunk Administration 2 H.323 Trunks
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
42
Task 3 — Assign Link via ethernet Data Module to the LAN
This task administers an ethernet data module for the connection between the C-LAN
board’s ethernet port (port 17) and the LAN. The data module associates a link
number and extension number with the C-LAN ethernet port location. This
association is used by the DEFINITY processor to set up and maintain signaling
connections for multimedia call handling.
The C-LAN ethernet port is indirectly associated with the C-LAN IP address via the
slot location (which is part of the port location) on the IP Interfaces screen and the
node name, which is on both the IP Interfaces and Node Names screens.
Begin
Task 3 Steps
> Open Data Module form — enter a da n
> Enter values
> Submit the screen
End
add data-module next Page 1 of X
DATA MODULE
Data Extension: 2377 Name: ethernet on link 2
Type: ethernet
Port: 01c0817_
Link: 2
Network uses 1’s for broadcast addresses?: y
Field Conditions/Comments
Type: This indicates the data-module type (ethernet) for this link.
Port: Ethernet connections must be assigned to port 17 on the C-LAN
circuit pack.
Link: The link number must be in the range 1 – 33 for G3r, or 1 – 25 for
G3si and G3csi, and not previously assigned on this switch.
Name: This field is information-only; it appears in lists generated by the
“list data module” command.
Network
uses 1’s for
broadcast
addresses?
Leave the default (y) if the private network contains only
DEFINITY switches and adjuncts. Set to n only if the network
includes non-DEFINITY switches that use the 0’s method of
forming broadcast addresses. See Appendix A, “Data Module -
type ethernet” for more information about this field.