Other Networking-Related DEFINITY Screens
293
Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000 CID: 77730
A Screens Reference
Other Networking-Related DEFINITY Screens
Communication Interface Links
This screen is display-only starting with Release 7. The fields are now administered on the Data Module screens
associated with the link. There is one Interface Link screen per System. Interface Links provide a physical
interface between the system and the other nodes in a DCS, ISDN, a Message Server Adjunct, a CMS, an ISDN
Gateway adjunct (supports CPN/BN), or AUDIX.
Link Indicates the interface link number that connects to another node in a DCS network, a
Message Server, CMS, ISDN Gateway, or AUDIX. Interface links always terminate
on a port in a PGATE circuit pack for G3r or on the NetPkt (or PI for X.25) circuit
pack for G3si.
Enable The link is enabled on the Data Module screen.
Page 1 of x
INTERFACE LINKS
Link Enable Est Extn Type Destination DTE Conn Name
Conn Number DCE Mod.
1: n n
2: n n
3: n n
4: n n
:
:
17:
Valid entries Usage
Display-only field.
Valid entries Usage
yy – link is enabled.
n n – link is not enabled. Message flow over the link is
suppressed.