Lucent Technologies Release 8.2 Server User Manual


 
Configuration 3: R8si<—x.25 —> R8r Gateway
<—ethernet—> R8si
3 C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
108
Switch 1 Task — Assign Link via ethernet Data Module to the LAN
This task administers an ethernet data module for ethernet connections. The data
module associates a link number with a port address, extension number, and node
name for the C-LAN port used for this connection.
Begin
Steps
> Open Data Module form — enter a da n
> Enter values.
> Submit the screen
End
add data module next Page 1 of x
DATA MODULE
Data Extension: 3391 Name: ethernet on link 3
BCC: 2
Type: ethernet
Port: 01b0117
Link: 3
Network uses 1’s for broadcast addresses? y
Field Conditions/Comments
Type: This indicates the data-module type for this connection.
Port: In this example, the C-LAN circuit pack is in slot 01b01; the
ethernet connection is through port 17.
Link: The link number must be in the range 1 – 33 (for R8r).
Name: Information-only; appears in list generated by the “list data
module” command.
Network
uses 1’s for
broadcast
addresses?
Leave the default (y) if the private network contains only
DEFINITY switches and adjuncts. Set to n only if the network
includes non-DEFINITY switches that use the 0’s method of
forming broadcast addresses. See Appendix A, “Data Module -
type ethernet” for more information about this field.