Lucent Technologies Release 8.2 Server User Manual


 
Switch-Node 1 Administration
221
Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000 CID: 77730
4 Networking Example
ethernet data module
IP Interface
Processor Channel Assignments
.
add data 1191
Page 1 of X
DATA MODULE
Data Extension: 1191
Name: ethernet on link 1_____________ BCC: 2
Type: ethernet
Port: 01c1517_
Link: 1_
Network uses 1’s for Broadcast Addresses? y
change ip-interfaces Page 1 of 2
IP Interfaces
Network regions are interconnected? n
En- Net
abled Type Slot Code Sfx Node Name Subnet Mask Gateway Addr Rgn
y
C-LAN 01c15 TN799 B ethernet1 255.255.255.0 192.168.200.1_ 1
_ _____ _____ _____ _ _________ 255.255.255.0 ___.___.___.___
_ _____ _____ _____ _ _________ 255.255.255.0 ___.___.___.___ _
_ _____ _____ _____ _ _________ 255.255.255.0 ___.___.___.___ _
_ _____ _____ _____ _ _________ 255.255.255.0 ___.___.___.___ _
_ _____ _____ _____ _ _________ 255.255.255.0 ___.___.___.___ _
_ _____ _____ _____ _ _________ 255.255.255.0 ___.___.___.___ _
_ _____ _____ _____ _ _________ 255.255.255.0 ___.___.___.___ _
change communications-interface processor-channels
Page 1 of X
PROCESSOR CHANNEL ASSIGNMENT
Proc Gtwy Interface Destination Session Mach
Chan Enable Appl. To Mode Link/Chan Node Port Local/Remote ID
1: y
audix__ s 1 5002 intuity 0____ _1_ 1__ 1_
2: y
gtwy-tcp 4_ _ 2 2___ _________ _____ _2_ 59_ __
3: y
gateway_ s 1 5031 intuity _ 0____ _3_ 3__ __
4: y gtwy-tcp 2_ s 1 5021 intuity 0____ _2_ 2__ __
:
:
10: y
mis___ _ s 1 5001 cms______ 0____ _1_ 1__ __
11: y
dcs___ _ 2 11__ _________ _____ _11 11_ 2_
12: y
gateway_ _ 2 12__ _________ _____ _12 12_ __
13: y gtwy-tcp 15 _ 2 13__ _________ _____ _13 13_ __
14: y
dcs___ _ s 4 5003 ppp41____ 0____ _14 14_ 4_
15: y
gtwy-tcp 13 s 4 5004 ppp41____ 0____ _15 15_ __
16: y gateway_ s 4 5005 ppp41_ __ 0____ _16 16_ __
:
64: _ _______ _ ___ ____ _________ 0
____ ___ ___ __